Fireground rescue training video featuring Rapid Intervention Crew (RIC) procedures, firefighter accountability, and downed firefighter retrieval. Critical firefighter safety training.

Know the standard

  • OSHA’s respiratory protection standard, 29 CFR 1910.134(g)(4), requires that at least two firefighters enter an IDLH atmosphere and stay in visual or voice contact with each other, with at least two more located outside. [1]
  • OSHA describes this as a minimum requirement. [1] Two firefighters standing by outside are the minimum number of personnel, not the same thing as a dedicated Rapid Intervention Crew, so check your department’s policy and how the rule applies in your state.

[1] OSHA, letter of interpretation on 29 CFR 1910.134(g)(4), April 29, 1998: osha.gov

💬

Questions to Ask While You Watch

Pause the video and use these discussion prompts for company drills or self-study. They are training suggestions from Free Fire Simulator and are not part of the video.

  • What is the difference between two-out and a dedicated Rapid Intervention Crew?
  • What tools, air supply and information does a RIC need before it is deployed?
  • How does Command track who is inside and where, so a RIC knows where to start?
  • How do clear Mayday calls and radio discipline change the speed of a rescue?
🔗

Related Training

🎥